Mennekes ACU Instructions D'installation page 62

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 74
Only with Mennekes Binary Protocol 3.9
Fig. 22: ACU backend – Trigger
Parameters
Description
Encrypt
To be activated if connection is to be
connection
encrypted via certificate.
Upload
Upload server certificate if connection is to
certificate
be encrypted.
Certificate
Entry of the certificate password.
password
Encrypting the connection
Precondition:
 You are in possession of a valid X.509 certificate. The
certificate is available on request from your backend
operator.
26
26
ACU Backend – NTP server
The "NTP server" tab has different structure depending
on the application protocol "Open Charge Point
Protocol v1.5" or "Mennekes Binary Protocol 3.9"
Parameters for the system time can be set in the "NTP
server" tab. Basically, it is possible to obtain the system time
automatically or to set the system time manually.
An incorrect system time in EDL21 mode leads to
malfunctions!
Only with Open Charge Point Protocol v1.5
Fig. 23: ACU backend – NTP server
Parameters
Description
Current
Display of the current system time.
system local
time
Timesource
Selection of the timesource.
 OCPP (time is taken from the OCPP
server)
 NTP server (time is taken from the set
NTP server)
 Manual (manual time setting)
Depending on the selection, the following
parameters are greyed out.
NTP server
Address of the NTP server.
(With timesource NTP server)
Manual
Manual entry of the system time.
(with timesource manual)