Only with Mennekes Binary Protocol 3.9
Fig. 20: ACU backend – Monitoring
Parameters
Description
URL
IP address of the monitoring server.
Port
List port of the monitoring server.
Name
Access name for server.
Pass
Access password for server.
Encrypt
To be activated if connection is to be
encrypted via certificate.
Interval
Update interval in minutes.
Upload
Upload X.509 certificate if connection is to
certificate
be encrypted.
Encrypting the connection
Precondition:
You are in possession of a valid X.509 certificate. The
certificate is available on request from your backend
operator.
ACU Backend – Remote control / Trigger
The "Remote control" tab is only available if the "Open
Charge Point Protocol v1.5" is selected. If you select
"Mennekes Binary Protocol 3.9", the "Trigger" tab will
appear instead.
The backend system can receive commands such as
"Remote authorization" and "Terminate charging process"
through the remote control interface.
Please consult your backend operator if you want to use
the remote control interface.
Only with Open Charge Point Protocol v1.5
Fig. 21: ACU backend – remote control
Parameters
Description
Encrypt
To be activated if connection is to be
connection
encrypted via certificate.
Remote port
Port number of the ACU.
Upload CA
Upload CA certificate if connection is to be
certificate
encrypted.
Upload
Upload server certificate if connection is to
certificate
be encrypted.
Certificate
Entry of the certificate password.
password
EN