Parameters
Description
SMSTel (on-
Input: If an authorization by SMS is
screen
desired, the telephone number to which
display)
the SMS is sent can be specified here.
Only in conjunction with "CPId".
CPId (on-
Input: Charging Point ID. If you need an
screen
SMS authorization, you can enter here the
display)
text to be displayed on the plain text
display of a Smart and Premium charging
station.
Only in conjunction with "SMSTel".
Reader type
Existing RFID card reader.
 Arygon Desfire
Earlier charging systems. Use only in
case of SCU replacement or socket
panel without RFID symbol.
 Elatec Multi 125
Special equipment.
 Elatec TWN4
MENNEKES Wallbox AMTRON
Premium, Trend.
 Elatec Multi ISO
Standard for MENNEKES charging
stations (Premium and Smart) or socket
panel with RFID symbol.
 No SCU Reader installed
Operation without RFID card reader or
the RFID card reader is deactivated.
 Emulated Reader
No RFID card is required for charging.
Local Auth
If reader type "Emulated Reader" is
UID
selected, the simulated UID can be entered
here.
Default: 0x00000000
12
12
Parameters
SCU flow
Autoselect
Energy Path
®
Description
Design of the charging station and
associated functions of socket panel
 Standard
Charging station with type 2 and
SCHUKO® charging sockets.
 Dummy Socket
Charging station with a permanently
connected cable and park plug.
 No Schuko
Charging station with type 2 charging
socket only (no SCHUKO® charging
socket).
Load path settings
 Combined Path (default)
Earlier charging systems without auto
switch (only one output is used for
controlling contactors). Permissible
charging cables are defined by the fuse
value.
 16 A and 32 A Path
New charging systems with auto
switch (each load path is controlled
separately). Charging cables of 20 A
and 32 A are acceptable.
 only 32 A Path
New charging systems with auto
switch.
Only the load path with 32 A is
controlled. Only charging cables of
32 A are acceptable.
 only 16 A Path
New charging systems with auto
switch.
Only the load path with 16 A is
controlled. Charging cables of 20 A
and 32 A are acceptable.