- Keep the arm in position and wait for the acoustic confirmation signal.
- Return the measuring arm to the rest position.
If the measuring arm is returned to the rest position after acquiring the data relating to
only one plane or if first the outer plane data then the inner plate data are acquired,
the "A 23" message is displayed and the acquired data are not considered.
- Perform a spin.
In the version with manual sensor, proceed as follows:
- press the
internal side (the distance LED lights up on the panel);
- position the end of the measuring arm on the plane chosen for the application of
the inner weight (Fig. 13/13a for ALU 1P = EASY ALU1 and Fig. 10/10a for ALU 2P =
EASY ALU2). In ALU 1P=EASY ALU1, the centre of the pawl on the end section of the
lever is taken as a reference for the centre line of the weight (version without the
weight holding device). In versions with the weight holding device, the centre line
of the weight must correspond with the centre of the groove in which the weight
will be placed. In ALU 2P = EASY ALU2 the rim edge is taken as a reference, since the
internal weight is of the conventional clip type.
Pay maximum attention when the end of the arm is being positioned in an area of
the rim free of discontinuity, so that the weight can be applied in that position.
- Read the internal distance d1 from the body on the rule;
- modify the value on the right display by pressing the
previously measured distance d1;
- press the
key again to prepare the machine for entry of the d2 distance relat-
ing to the outer side (the distance LED lights up on the panel);
Operator's manual MT 3100 - MT3200
14
key to prepare the machine for entering distance d1 relative to the
Pe not between P1 and P2
keys to get the
14a
83