- modify the displayed distance value by pressing the
read number is set;
- on completion, press
of the new dimensions, or
UNBALANCE DISPLAY IN GRAMS/OUNCES
The setting for the visualisation of the unbalance values in grammes or ounces is made
by keeping the key
When started up, the machine is set to display the unbalance values at five-gramme
increments, i.e. rounded to the nearest multiple of five (or quarters of an ounce if
visualised in ounces).
In this condition, the first four grams of unbalance are not displayed since an appropriate
threshold, indicated by illumination of the
The
key can be pressed to eliminate the threshold (the illuminated indication
"x5"; "oz/4" goes out) and the unbalance values will be displayed gram by gram (or in
tenths of an ounce if display in ounces is active).
Pressing the key consecutively allows the user to set one display mode or the other.
Press the
key on the display together with the key on the left side and hold them
down until the braking phase starts. If one of the two contacts, or both, is released
during the wheel start-up or reading phase, the message "A Cr" will appear and the
brake will be automatically activated.
WARNING
Do not operate the machine if the safety device has been tampered with.
WARNING
During machine use, personnel may not be present in the area enclosed by the
sectioning in Fig. 5a.
Operator's manual MT 3100 - MT3200
to display the unbalance values recalculated on the basis
to perform a wheel spin.
pressed for about five seconds.
ROUNDING OFF
WHEEL SPIN
LED on the display panel, is activated.
buttons until the
77