Enable programming mode (see section 11 "Programming",
paragraph "b) Enabling/exiting programming mode"). The
LED indicator (2) will then flash red.
Example:
Press the
Enter the desired function for the access mode:
0 = Access via transponder or fingerprint (default setting)
1 =Access via fingerprint only
2 = Access via transponder only
Press the
will briefly turn green and then flash red (programming mode).
To exit programming mode, press the
indicator (2) will switch to constant red to indicate that the
code lock is in standby mode.
n) Scheduling the timer for the relay output or
switching to toggle mode
The potential-free changeover contact of the code lock can be
activated with a transponder or a user fingerprint.
The following functions are possible:
The changeover contact is activated for 2....99 seconds
(default setting 5 seconds); optimal e.g. for a door opener.
The changeover contact is activated for 100 ms (pulse mode);
optimal e.g. for controlling an alarm system..
key. The LED indicator (2) will turn orange.
key to confirm your entry. The LED indicator (2)
key. The LED