• Connect the product to the screw terminals. For more
information, refer to section 8 "a) Connection".
• Wire the connection cables according to the following circuit
examples. Ensure that there is suitable insulation (e.g. heat
shrink tubing).
• A protective diode is included for connecting a door opener.
This protects the code lock from damage caused by voltage
peaks.
• Pay attention to the correct polarity. Refer to following
connection examples (the white ring on the protective diode
must point in the direction of the positive terminal/+ when
connecting).
Caution! Never switch the mains voltage via the
potential-free changeover contact! This may cause
a fatal electric shock! Refer to the "Technical data"
section for information on the permissible contact
rating.
Use suitable cables with different colours. Note the
colours and store this information together with these
instructions. When connecting the cables, pay attention
to the correct polarity (plus/+ and minus/-).
• Attach the code lock to the mounting plate. Ensure that the
cables are not pinched. The code lock can be fixed to the
mounting plate using the fixing screw (4) on the bottom. Use
the hex key provided, which is designed for the fixing screw.