Bead breaker unit is underpowered, it does not break the bead and is
leaking air
Perform the checks in the previous point: "Bead breaker unit not working".
Cylinder seals worn.
➥ Renew seals.
➥ Renew bead breaker cylinder.
Bead breaker cylinder leaks air around the rod
Air seal worn.
➥ Renew seals.
➥ Renew bead breaker cylinder.
Gear unit noisy. The table top makes 1/3 of a revolution and then stops
Gear unit seizing.
➥ Renew gear unit.
Table top fails to clamp wheels
Handle engagement unit faulty.
➥ Check that it is synchronised properly.
➥ Replace the plate in the turntable.
➥ Check that there are no burrs.
➥ Replace the clamping handle.
Table top mounts or demounts tyres with difficulty
Insufficient belt tension.
➥ Adjust belt tension or renew it.
Vertical slide lifts too little or too far from rim
Clamping plate not adjusted.
➥ Adjust plate.
➥
UK
Recalibrate
.
The vertical slide has difficulty rising
Defective clamping plate.
➥ Renew plate.
Clamping plate not adjusted.
➥ Adjust plate.
Vertical and horizontal limit stops do not operate
No air passing through clamping handle / valve.
➥ Check the hose circuit.
➥ Replace handle / valve.
Column does not tilt
Column tilting cylinder faulty.
➥ Replace column tilting cylinder.
No air supply to cylinder.