part nr 4-121505. Warning. Do not use below floor level.
1.2.c. ELECTRICAL AND PNEUMATIC
CONNECTIONS
The dimensions of the electric hook-up
used must be suitably sized in relation to:
• the electric power absorbed by the ma-
chine, indicated on its data plate (Fig. 1);
• the distance between the machine and
the power supply hook-up point, so that
voltage drops under full load do not ex-
ceed 4% (10% during start-up) compared with
the rated voltage specified on the data plate.
- The operator must:
• it a power plug on the power supply lead in
compliance with the relevant safety standards;
• connect the machine to its own electrical con-
nection - A, Fig. 2 - and fit a differential safety
circuit-breaker with 30 mA residual current;
• it fuses to protect the power supply line,
rated as indicated on the general wiring dia-
gram in this manual;
• connect the machine to an industrial socket;
the machine must not be connected to do-
mestic sockets.
FOR CANADIAN MARKET ONLY:
•
The machine must be hard wired connec-
tion and fit a differential, 20A maximum,
safety circuit-breaker with 30 mA residual
corrent.
•
Fit a fuse to protect the power supply line,
rated as indicated on the general wiring
diagram in this manual.
An effective grounding connection is essential for correct operation of the machine.
Make sure the available pressure and the rendered capacity of the compressed air system
are compatible with those required for correct machine operation - see the "Technical Data"
section. For correct machine operation, the compressed air supply line must provide a