Standard Working Sequence - Corghi Exact 70 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Eichstädt Elektronik - Professionelle Kfz-Diagnosegeräte
For steel rims or rims with projecting edges, the
clamps should be tightened from the inside (fig.29);
for alloy rims tighten from the outside (fig.30) and
for rims with plastic covers connect from the inside
with the pins turned round (fig.31).
If necessary, tap on the clamp to insert the claw
between the rim and the bead of the tyre; in this
case, it is best to fit the clamp separately from
the sensor.
After fitting the four clamp and sensor units, con-
nect the wires between the rear and front sensors
and between the front sensors and the central unit
(fig.32) Switch on the sensors by pressing the on key
(A fig.25). To switch the sensors off, press the on key
again. If the wires are reconnected without switching
the sensors off, they will switch on immediately with
no need to press the on key.
N.B. There are two pairs of wires of different lengths;
their working position is irrelevant.
For radio versions, fit the 4 clamp-sensor units and
switch on the sensors using the on key during this
operation. Radio sensors may switch off when the on
button is pressed, because a battery is completely
flat or due to the energy saving device. In all cases,
to switch the sensors back on (provided the battery
is not flat), press the on key.
STANDArD worKING
SEQUENCE
Alignment procedure for 2-axle vehicles (cars).
1) Aligner switch-on
2) Start work.
3) Databank / Job record
4) Preparation for wheel alignment
5) wheel diameter input
6) Compensation
7) Chassis height input
8) Angle measurement with steering locked to 10°
or 20°
9) Data summary
10) Rear axle measurement
11) Front axle measurement
12) Angle measurement with steering locked to 10°
or 20°
13) Front axle measurement
14) Print out of data measured
Operator's Manual EXACT 70
Power up the equipment using the main switch
(H fig.22).
wait a few seconds to allow the monitor to switch on
and the computer to load the program.
In this stage, the central unit runs a functional self-
diagnostics test and loads the operating system; if
everything is in order, the "Main menu" screen will
appear (fig.33).
If the user set-up field "Alignment customisation
procedure/Lift test" = YES, the program will auto-
matically open the "Lift Check" page, see "Lift and
Sensor Check" section.
To access this function from the rest of the program
select the
Select the wheel alignment mode
procedure
"demo" mode, for which the sensors are not required.
The "demo" mode is indicated by the
symbol in the status bar.
maintenance utilities, and wheel aligner customi-
sation.
down all the applications open and switches off
the wheel aligner.
modes. The truck and trailer modes are only enabled
if the
The instructions for this mode are provided in the
manual supplied with the kit.
http://www.eichstaedt-elektonik.de
(1) Switching on the aligner
(2) work start selection (fig.33)
icon or the F9 key.
and start work
restarts the previous job.
and
enable and disable the
and
access the service and
ends execution of the program, shuts
allows selection of the wheel alignment
truck upgrade has been installed.
and
.
EN