Installation Space; Ambient Working Conditions; Electrical Hook-Up - Corghi Exact 70 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

MER: "ON" MERCEDES program on, "OFF" pro-
gram off.
PHEATON: "ON" Vw Phaeton and Touareg program
on, "OFF" program off.
ANIM: "ALL" display of alignment adjustment help
animations on, "FIN" display of non-moving align-
ment adjustment help diagrams, "OFF" alignment
adjustment help graphics off.
TRUCK:"ON" truck/trailer program on, "OFF" pro-
gram off.
ROMESS: "ON" ROMESS CM-09606 inclinometer
automatic connection program on, "OFF" program
off.
ASANTW: "ON" ASA Network program on, "OFF"
program off.
RADAR: "ON" vehicle anti-collision radar calibration
program on, "OFF" program off.
CUSTOM: type of wheel aligner customisation.
BD YEAR: year of the latest databank upgrade, if
"DEMO" the aligner card has not been inserted or is
not functioning correctly.

Installation space

WARNING
The installation site must be chosen in compli-
ance with local regulations regarding safety in
the workplace.
The floor must be able to withstand a load equal
to the sum of the weight of the equipment itself
and the maximum payload, bearing in mind the lift
support surface area and anchor fixtures used.
Place the aligner in the designated work position
and make sure that the rear panel of the equipment
is at least 10cm away from the nearest wall.
IMPORTANT: for correct, safe use of the equipment,
users must ensure a lighting level of at least 300 lux
in the place of use.
54
Eichstädt Elektronik - Professionelle Kfz-Diagnosegeräte
http://www.eichstaedt-elektonik.de
ATTENTION
Make sure that there are no permanent magnets,
electromagnets or large heat sources close to the
equipment (they might damage the program disk
and the Personal Computer beyond repair).

Ambient working conditions

Relative humidity 20% - 80%.
Temperature range 0°C - 40°C.
WARNING
Use of the equipment in a potentially explosive
atmosphere is not permitted.

ELECTrICAL HooK-UP

The manufacturer pre-sets the aligner to operate with
a power supply of 230V AC. To change this setting,
refer to the "installation" section.
WARNING
Any connections to the workshop electrical board
are the customer's responsibility, and must be made
by staff qualified in accordance with the relevant
legal requirements.
- The electric hook-up must be suitably rated in
relation to:
• The machine input power, specified on the
machine data plate.
• The distance between the equipment and the
electric hook-up point, so that voltage drops
under full load do not exceed 4% (10% during
start-up) below the rated voltage specified on
the dataplate.
- The user must:
• fit a power plug in compliance with the current
regulations on the power supply lead;
• connect the equipment to its own electrical con-
nection having a specific automatic differential
circuit-breaker, with sensitivity 30 mA;
• fit protection fuses to protect the power supply
line, rated in accordance with the instructions
provided in the general wiring diagram in this
manual;
Operator's Manual EXACT 70

Publicité

Table des Matières
loading

Table des Matières