6.7.2
UL type label
Example:
Figure 8:
UL type label (example)
6.7.3
UL additional label
Example:
Figure 9:
UL additional label (example)
6.8
Electrical data
WARNING!
Only circuits with limited power may be used for UL approved components according to "NEC Class 2".
6.8.1
Electrical data without bus control 24 V DC
Protection class
Connections
Control valve
Operating voltage
Power input
Input resistance
for set-point value signal
22
Type; Features of the type code applicable to UL and ATEX
8694 -E3-...-0
PU02
Single act Pilot 3.0 24V
Pmax 7 bar
Tamb -10 - +55 °C
CE
S/N 1001
00123456
W15MA
Degree of protection
Circuit with limited power
Supply voltage device
3 as per DIN EN 61140 (VDE 0140-1)
Cable gland M16 x 1.5, wrench size 22 (clamping area 5 – 10 mm)
with screw-type terminals for cable cross-sections 0.14 – 1.5 mm²
Circular plug-in connector (M12 x 1, 8-pole)
24 V DC ± 10% - max. residual ripple 10 %
≤ 3.5 W
75 Ω at 0/4 - 20 mA / 12 bit resolution
english
Control function; pilot valve;
Supply voltage pilot valve
Max. operating pressure
Max. ambient temperature
Serial number; CE mark
Identification number; Date of manufacture (encoded)
Bar code
Type 4X enclosure
NEC Class 2 only
Supply voltage: 24V
Type 8694
Technicaldata