TeChNiCal daTa

The following values are indicated on the type label:
• Ambient and medium temperature, voltage
± 10 %), kind of current, pressure.
Use as return flow valve: In combination with a feed flow valve in an electric
1)
series connection, the voltage value of the type label is half that of the relevant
power supply.
Materials
Body
Seat seal
Body seal
Coil jacket
Media
Heating oils DIN 51603 Part 1-6 at a viscosity:
for an output of ≤ 12 watt: 1.2 to 22 cST
for an output > 12 watt: 1.6 to 76 cST
(other media by arrangement with the Bürkert sales office)
Circuit function 2/2-way valve
A (NC)
2(A)
1(P)

4.2 Type label standard

Body material
Sealing material
Orifice
Circuit function
Type
6027 NC 3,0 EF MS
G1/8 PN0-30 bar IP65
110-120V 50Hz 20W
00YYYYYY
00XXXXXX
Id. Number
Customer article number (optional)
Voltage, Frequency, Output
Connecting thread, Operating
pressure, Protection class
6

5.2 fluid installation

Installation position: any, actuator preferably upwards.
Procedure:
Prior to installation check pipelines for dirt and clean if necessary.
Install a dirt trap to prevent malfunctions (0.2 ... 0.4 mm).
Only use new seals.
Hold the device with a open-end wrench on the body and screw
into the pipeline.
Observe flow direction:
When used in the feed flow: from 1 → 2 (from P → A) or in the
direction of the arrows.
When used in the return flow: from 2 → 1 (from A → P) or in the
opposite direction of the arrows.
note!
Caution risk of breakage!
• Do not use the coil as a lifting arm.
If installed in the wrong direction it can lead to a malfunction of
the firing equipment.
• Observe direction of installation.
(tolerance
1)
Brass or stainless steel
PTFE
FKM
Epoxy or polyamide
B (NO)
2(B)
1(P)
W14LP
english
Protection class
IP65 in accordance with DIN EN 60529 / IEC
60529 with cable plug, e.g. Bürkert Type 2508
4.1 Type label approval (depending on
version)
Register number
Permitted ambient temperature
Max. permitted medium temperature
english
5
iNsTallaTiON
5.1 safety instructions
Danger!
Risk of injury from high pressure in the equipment!
▶ Before loosening the pipes and valves, turn off the pressure and
vent the lines.
Risk of injury due to electrical shock!
▶ Before reaching into the device or the equipment, switch off the
power supply and secure to prevent reactivation.
▶ Observe applicable accident prevention and safety regulations for
electrical equipment.
Warning!
Risk of injury from improper installation!
▶ Installation may be carried out by authorized technicians only and
with the appropriate tools.
Risk of injury from unintentional activation of the system and an
uncontrolled restart!
▶ Secure system from unintentional activation.
▶ Following assembly, ensure a controlled restart.
5.3 electrical connection of the cable plug
Warning!
Risk of injury due to electrical shock!
▶ Before reaching into the system, switch off the power supply and
secure to prevent reactivation.
▶ Observe applicable accident prevention and safety regulations for
electrical equipment.
If the protective conductor is not connected, there is a risk of electric
shock!
▶ Always connect protective conductor and check electrical continuity.
Seal
english
Certification mark
T med. Max. 160°C
T Umg. -15°C bis 60°C
Reg.Nr. XXXXX
0036
Inspection body
Approved cable plug
e. g. Type 2508
max. 1 Nm