Type 8694
Installation
2. Install sealing rings
→
Pull the form seal onto the actuator cover (smaller diameter points upwards).
→
Check that the O-rings are correctly positioned in the pilot air ports.
When the positioner is being installed, the collets of the pilot air ports must not be fitted to the actuator.
Pilot air port
Caution:
collets must not be
fitted !
Figure 21:
Installation of the sealing rings, series 2103, 2300 and 2301
3. Install positioner
→
Align the puck and the positioner until
1. the puck can be inserted into the guide rail of the positioner (see "Figure 22")
and
2. the connection pieces of the positioner can be inserted into the pilot air ports of the actuator (see also
"Figure 23").
NOTE!
Damaged printed circuit board or malfunction.
▶ Ensure that the puck is situated flat on the guide rail.
Figure 22:
Aligning the puck
Form seal
Guide rail
Puck
Installation of the form
seal
english
35