Information about the communications software:
The switching position of the DIP switch has priority over the settings via the communications software.
If the values of the sealing function (CUTOFF) or the correction characteristic (CHARACT) are changed
via the communications software, the corresponding function must be active (DIP switches set to ON).
The effective direction of the set-point value (DIR.CMD) can be changed via the DIP switches only.
If the correction characteristic (CHARACT) is not changed via the communications software, a linear char-
acteristic is saved when DIP switch 3 is set to ON.
A detailed description of the functions can be found in the chapter entitled "Basic functions".
Figure 17:
Position of the seal in the body casing
→
Version 1:
Check that the seal is correctly positioned in the body casing.
NOTE!
Breakage of the pneumatic connection pieces due to rotational impact.
▶ When unscrewing and screwing in the body casing or transparent cap, do not hold the actuator of the pro-
cess valve but the connection housing.
Damage or malfunction due to penetration of dirt and humidity.
▶ To observe degree of protection IP65 / IP67, screw the transparent cap in all the way.
→
Close the device (assembly tool: 674077
The assembly tool (674077) is available from your Bürkert sales office.
12)
30
).
12)
english
Body casing
Seal
body casing
Connection housing
Type 8694
Controlanddisplayelements