Type 8694
Technicaldata
6.6
Pneumatic data
Control medium
Dust content
Quality class 7
Water content Quality class 3
Oil content
Quality class X
Temperature range
of the control medium
Pressure range
of the control medium
Air output of pilot valve
Connections
6.7
Type labels
6.7.1
Type label standard
Example:
Supply voltage / Control
Identification number
Figure 7:
Example of type label
neutral gases, air
Quality classes in accordance with ISO 8573-1
max. particle size 40 µm, max. particle density 10 mg/m³
max. pressure dew point
- 20 °C or min. 10 °C below the lowest operating temperature
max. 25 mg/m³
-10 – +50 °C
3 – 7 bar
7 l
/ min (for aeration and deaeration)
N
(Q
- value according to definition for pressure drop from 7 to 6 bar
Nn
absolute)
optional: 130 l
/ min (for aeration and deaeration)
N
(only single-acting)
Plug-in hose connector Ø6 mm / 1/4"
Socket connection G1/8
Type
8694 24 V DC
single act
Pilot 0,6
Pmax 7bar
Tamb 0°C - +60°C
CE
S/N 001000
00185134
W14UN
Control function - Pilot valve
Max. operating pressure
Max. ambient temperature
Serial number - CE mark
Bar-code
english
21