Using the keypad XT EMZ9371BC − Parameter setting
Change and save parameters
All parameters for controller setting or monitoring are saved in codes. The codes are
numbered and labelled in the documentation with a "C". Some codes store the parameters
in numbered subcodes", so that a clear parameter setting is ensured (e. g.: C0517 User
menu).
The codes are described in detail in the system manual of the drive controller.
)
Note!
Your settings in the menus are always stored in the parameter set 1.
If you want to store settings in the parameter set 2, 3 or 4, two menus can be
used:
In menu 2 "Code list" it is possible to access to all available codes.
l
In menu 7 "Param managm" it is possible to copy parameter set 1 into the
l
oter parameter sets.
– Please note, that with copying the "own basic setting" will be
overwritten by the settings of parameter set 1!
Step
1.
Select menu
2.
Change to the code level
3.
Select code or subcode
4.
Change to parameter level
5.
If SHPRG is displayed, inhibit controller
6.
Change parameters
7.
Accept changed parameter
Display of SHPRG or SHPRG
8.
If necessary, enable controller
9.
Change to the code level
10.
Change further parameters
L
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Keys
Action
z y Z Y
Select the desired menu with arrow keys
Z
Display of first code in the menu
y z
Display of current parameter value
V
S
The drive is idling
Z Y
A
Move cursor under the digit to be changed
y z
B
Change digit
T y
Change digit quickly
T z
p T V
Confirm change to accept parameter
Display "OK"
p
−
The parameter was accepted immediately
Display
U
The drive should be running again
V
A
Display of operation level
V
B
Display of the code with changed parameters
Restart "loop" at step 1. or step 3.
EDK82EV113 DE/EN/FR 8.1
7
Commissioning
131