154
Annexe C –
DTC
P2685
Actuator Supply Voltage 3 (HSD3) Low
P2686
Actuator Supply Voltage 3 (HSD3) High
P2714
Pressure Control Solenoid 4 (PCS4) Stuck Off
P2715
Pressure Control Solenoid 4 (PCS4) Stuck On
P2718
Pressure Control Solenoid 4 (PCS4) Control Circuit Open
P2720
Pressure Control Solenoid 4 (PCS4) Control Circuit Low
P2721
Pressure Control Solenoid 4 (PCS4) Control Circuit High
P2723
Pressure Control Solenoid 1 (PCS1) Stuck Off
P2724
Pressure Control Solenoid 1 (PCS1) Stuck On
P2727
Pressure Control Solenoid 1 (PCS1) Control Circuit Open
P2729
Pressure Control Solenoid 1 (PCS1) Control Circuit Low
P2730
Pressure Control Solenoid 1 (PCS1) Control Circuit High
P2736
Pressure Control Solenoid 5 (PCS5) Control Circuit Open
P2738
Pressure Control Solenoid 5 (PCS5) Control Circuit Low
P2739
Pressure Control Solenoid 5 (PCS5) Control Circuit High
P2740
Retarder Oil Temperature Hot
P2742
Retarder Oil Temperature Sensor Circuit – Low Input
P2743
Retarder Oil Temperature Sensor Circuit – High Input
P2761
TCC PCS Control Circuit Open
P2763
TCC PCS Control Circuit High
P2764
TCC PCS Control Circuit Low
P278A Kickdown Input Failed ON
P2793
Gear Shift Direction Circuit
P2808
Pressure Control Solenoid 6 (PCS6) Stuck Off
P2809
Pressure Control Solenoid 6 (PCS6) Stuck On
P2812
Pressure Control Solenoid 6 (PCS6) Control Circuit Open
P2814
Pressure Control Solenoid 6 (PCS6) Control Circuit Low
P2815
Pressure Control Solenoid 6 (PCS6) Control Circuit High
U0001
Hi Speed CAN Bus Reset Counter Overrun (IESCAN)
U0010
CAN BUS Reset Counter Overrun
U0100
Lost Communications with ECM/PCM (J1587)
Lost Communication with Gear Shift Module
U0103
(Shift Selector) 1
U0115
Lost Communication with ECM
Lost Communication with Gear Shift Module
U0291
(Shift Selector) 2
U0304
Incompatible Gear Shift Module 1 (Shift Selector) ID
U0333
Incompatible Gear Shift Module 2 (Shift Selector) ID
Invalid Data Received From Gear Shift Module
U0404
(Shift Selector) 1
Invalid Data Received From Gear Shift Module
U0592
(Shift Selector) 2
Codes d'anomalie de la transmission Allison
Description
CHECK
Inhibited Operation
TRANS
Description
Light
Yes
DNS, SOL OFF (hydraulic default)
Yes
DNS, SOL OFF (hydraulic default)
Yes
DNS, RPR
Yes
DNS, SOL OFF (hydraulic default)
Yes
DNS, SOL OFF (hydraulic default)
Yes
DNS, SOL OFF (hydraulic default)
Yes
DNS, SOL OFF (hydraulic default)
Yes
DNS, RPR
Yes
DNS, RPR
Yes
DNS, SOL OFF (hydraulic default)
Yes
DNS, SOL OFF (hydraulic default)
Yes
DNS, SOL OFF (hydraulic default)
Yes
Inhibit retarder operation
Allow 2 through 6, N, R. Inhibit
Yes
retarder and TCC operation
Yes
Inhibit retarder operation
No
None
No
Use default retarder temp values
No
Use default retarder temp values
Yes
Inhibit TCC operation
Yes
Inhibit TCC operation
7-speed: Allow 2 through 6, N, R.
Yes
Inhibit TCC operation
No
Inhibit kickdown operation
Ignores PWM input from shift
Yes
selector
Yes
DNS, RPR
Yes
DNS, RPR
Yes
DNS, SOL OFF (hydraulic default)
Yes
DNS, SOL OFF (hydraulic default)
Yes
DNS, SOL OFF (hydraulic default)
No
Use default values, inhibit SEM
No
Use default values, inhibit SEM
Yes
Use default values
Maintain range selected, observe
Yes
gear shift direction circuit
Yes
Use default values
Maintain range selected, observe
Yes
gear shift direction circuit
Yes
Ignore shift selector inputs
Yes
Ignore shift selector inputs
Maintain range selected, observe
Yes
gear shift direction circuit
Maintain range selected, observe
Yes
gear shift direction circuit