Starting Up Again; Disposal; Maintenance - salmson Rocsan lix Manuel D'installation Et Mise En Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
English
BEWARE of burns!
The housing components can heat up to well above
40 °C. there is a danger of burns! After switching
off, let the product cool down to ambient tempera-
ture.
7.2.1. Removal
Portable wet installation
Products in portable wet installations can be lifted out of the pit
after being disconnected from the mains power supply and emp-
tying the discharge pipe. You may have to disconnect the hose
first. The use of appropriate hoisting gear may be necessary.
Stationary wet installation
Products in stationary wet installations with suspension units are
raised out of the pit using appropriate lifting gear. During lifting,
always hold the power cable slightly taut to prevent it from being
damaged.
The operating area does not have to be emptied especially for
this purpose. The shut-off valves in the intake and discharge pipe
must be closed to prevent the operating area from overflowing or
the discharge pipe being emptied.
7.2.2. Return delivery/storage
Returning the product
For shipping, the parts must be packed and sealed in sufficiently
large, non-tearing plastic sacks to prevent leakages. Shipping
must be carried out by carriers who have been briefed accordingly.
Please also refer to the "Transport and storage"
section.
Storage
• Clean the pump thoroughly, decontaminating it if neces-
sary.
• Store it in a clean, dry place protected from frost.
• Place it down vertically onto a firm foundation and secure
it against falling.
• Seal the intake and discharge ports tight with suitable
material (such as foil).
• Support the power cables at the cable lead-in to pre-
vent permanent deformation and protect the ends from
moisture.
• Protect the pump from direct sunshine to prevent the
elastomer parts and housing coating from becoming
brittle.
Please also refer to the "Transport and storage"
section.
7.3.

Starting up again

Clean the product of dust and oil deposits before starting up
again. Then carry out all the maintenance tasks as described
in the "Maintenance" section.
Once this work has been completed, the product can be installed
and connected to the electricity supply by an electrician. This
work must be carried out in accordance with the "Installation"
section.
The product must be switched on as described in the "Start-up"
section.
The product may only be restarted if it is in perfect
condition and ready for operation.
7.4.

Disposal

7.4.1. Lubricants
Oils and lubricants must be collected in appropriate containers
and properly disposed of in terms of EC Directive 75/439/EEC as
well as in compliance with the provisions of sections 5a and 5b of
the German Waste Act or the applicable local laws.
7.4.2. Protective clothing
Protective clothing worn for cleaning and maintenance work is
to be disposed of in accordance with the German Waste Code
TA 524 02 and EC Directive 91/689/EEC.
7.4.3. Product
Proper disposal of this product avoids damage to the environment
and risks to personal health.
• Make use of the services or the advice of public or private
waste disposal companies for the disposal of the product
or parts of it.
• More information about proper disposal can be obtained
from the urban administration, the waste disposal au-
thorities or from the supplier from whom the product was
purchased.
8.

Maintenance

Before performing maintenance or repair work, switch off and
dismount the product as described in the section entitled "Final
shutdown/disposal".
After completing maintenance or repair work, the product must
be installed and connected according to the "Installation" section.
The product must be switched on as described in the "Start-up"
section.
Maintenance or repair work must be carried out by an authorized
service center, Salmson customer service or a qualified specialist.
Maintenance or repair work and/or constructional
changes that are not listed in this operating and
maintenance manual may only be carried out by the
manufacturer or by authorized service centers.
ELECTRoCUTIon hazard!
There is a risk of fatal electric shocks when per-
forming work on electrical devices. With all main-
tenance or repair work, the unit must be discon-
nected from the mains and secured against being
switched on again without permission. Damage to
the power supply cable may only be rectified by a
qualified electrician.
45

Publicité

Table des Matières
loading

Table des Matières