Operation
4. In the Establish connection dialog box, check the
identity of the energy manager again using the
identification number (SKI) and then select the
option Connect.
�� The energy manager is successfully con-
nected and the status Energy manager con-
nected is displayed.
The energy manager settings (e.g. charging
current, overload protection and optimized
charging) are applied to the charger.
Disconnecting the connection to the energy man-
ager
In private mode, the connection to the energy man-
ager can be disconnected in the charger's Web Appli-
cation.
b Private mode is activated.
1. Navigate to Connections e Energy manager in
the charger's web application.
�� The connected energy manager is displayed
in the Available energy managers list.
2. Select Disconnect.
�� The connection between the energy man-
ager and the charger is disconnected.
Settings
System
Change password
Changes the login password for the Web Applica-
tion. The initial password from the letter containing
access data is overwritten with the newly selected
password.
e
Select Change and enter new password.
28
Specifying the language and country
Field
Explanation
Language
Selection of the lan-
guage for the Web Ap-
plication.
Country
The country of use. The
configuration settings
are country-specific. If
the specification devi-
ates from the actual
place of use, it is possi-
ble that some settings
will not be available.
Regulating power consumption
Activate sleep mode to save electricity.
If sleep mode is activated and no further action is
taken via the charger or Web Application for 10 mi-
nutes, the charger enters into sleep mode. After this,
the charger can no longer be accessed via the Web
Application.
e
Activate the function Standby mode.
The device requires some time to leave sleep
mode and restore operational readiness.
Information
After a prolonged period of non-use, the charger
switches automatically to standby mode. Press the
Power button to restart.
Activate reset to factory settings
By activating this function, it is possible to reset to
factory settings directly on the charger. If the func-
tion is deactivated, a reset to factory settings on the
web application is restricted.
e
Activate the function Reset to factory settings.
g Please refer to the chapter "Resetting to fac-
tory settings" in the operating instructions for
the Porsche Mobile Charger Plus.
XXXLINKXXX Refer to chapter "Resetting to fac-
tory settings" on page 6.
Charging
Grid status
The information on the grid status presented here is
automatically detected by the device.
Display
Explanation
Grid phases
Number of supply cable
phases.
Cable type
Type of vehicle charg-
ing cable. The cable
type delivers impor-
tant information for
the maximum charging
current setting.
Reason for reduced
The number 0 indicates
charging power
that the charging power
is not restricted.
A number > 0 indi-
cates that the charging
power is impaired by
overheating.