ROM supplied with the aligner.
If the CD-ROM release is more recent than the
release installed, update the aligner software.
Detailed information about the software update
procedure is provided in the leaflet accompany-
ing the CD-ROM.
Aligner information Window
The
,
the system configuration:
CARD: card number 1 is the wheel aligner's main
USB KEY; card number 2 (if any) is an update
USB KEY.
HEADER: "MAS" aligner main USB KEY, "AGG"
update USB KEY.
SERIAL: USB KEY serial number. For main USB
KEY this number is unique. For update USB KEY
the number is 0 when they are new, while after
use it becomes the same as that of the main card
that has been updated.
DATE: USB KEY creation date.
CUSTOM: type of wheel aligner customisation.
BD YEAR: year of the latest databank update,
if "DEMO" the aligner USB KEY has not been
inserted or is not functioning correctly.
Installation space
WARNING
Choose the place of installation in strict obser-
vance of local regulations regarding safety in
the workplace.
The floor must be able to withstand a load
equal to the sum of the weight of the equipment
itself and the maximum payload, bearing in
mind the lift support surface area and anchor
fixtures used.
Place the aligner in the designated work position
and make sure that the rear panel of the equip-
ment is at least 10cm away from the nearest wall.
IMPORTANT: for correct, safe use of the equip-
ment, users must ensure a lighting level of at
least 300 lux in the place of use.
CAUTION
Make sure that there are no permanent mag-
nets, electromagnets or sources of heat in the
42
and
icons display
vicinity of the machine as these could cause
irreparable damage (they might irreparably
damage the programme disk and the Personal
Computer).
Ambient working conditions
Relative humidity 20% - 80%.
Temperature range 0°C - 40°C.
WARNING
The machine must not be operated in potentially
explosive atmosphere.
ELECTRICAL HOOK-UP
The manufacturer pre-sets the aligner to operate
with a power supply of 230V AC. To change this
setting, refer to the "installation" section.
WARNING
Any connections to the workshop electrical
board are the customer's responsibility, and
must be made by staff qualified in accordance
with the relevant legal requirements.
- The electric hook-up must be suitably rated
in relation to:
• The machine input power, specified on the
machine data plate.
• The distance between the equipment and
the electric hook-up point, so that voltage
drops under full load do not exceed 4% (10%
during start-up) below the rated voltage
specified on the dataplate.
- The user must:
• Fit a power plug in compliance with the cur-
rent regulations on the power supply lead.
• Connect the equipment to its own electri-
cal connection having a specific automatic
differential circuit-breaker, with sensitivity
30 mA.
• Fit protection fuses to protect the power
supply line, rated in accordance with the
instructions provided in the general wiring
diagram in this manual.
• Provide the workshop's electrical system
with a grounding circuit in good working
order.
- In order to prevent the equipment being used
by unauthorised personnel, it is advised to
disconnect the power supply plug when the
equipment remains idle (switched off) for long
Operator's manual EXACT LINEAR