Control

The control unit monitors and controls the
automatic operation of the water recycling
system.
On the display you can:
read system status messages
set operating values
test functions.
Operator controls and displays
1
Four-line display - example: *1/2***Menu
name**** - Submenu 1 - Submenu 2 -
Submenu 3
2
LED green = system operates in automatic
mode. LED flashes = manual mode or
running-in phase.
3
LED red = fault – the system stops when
the signal sounds!
4
Menu step up
5
Decrease set value
6
Confirm entry
7
Increase set value
8
Menu step down
Navigation:
Using the
or
cursor in front of the menu item
wanted.
Using the
button, call the menu item.
In the submenu move the cursor in
front of the function wanted, using the
or
buttons.
Activate the function with the
300108/AV/Draft
buttons, move the
button.
Operating Manual AC 3000-13500
Using the
or
decrease the set value .
Save the set value with the
Press the
button several times to go
to the main menu.
Code prompt:
Some procedures require you to enter a code:
Set the code using the
buttons.
Confirm the code with the
The code of the control is:
1 2 3 4
buttons, increase or
button.
and
button.