F: Pressure pump keeping starting
Fault
Pressure pump keeps starting
at short intervals
Pressure pump keeps starting
at short intervals
G: Leakage
Fault
Leakage of system components
(except tanks)
Tank leakage
Water escapes during drinking
water top-up (tank 3)
300108/AV/Draft
Check (possible causes)
Leakage in the domestic
installation (e.g. toilet flush
system does not fully close)
Leaky valve at filter backwash
Check (possible causes)
Identify leakage
Identify leakage
Check position of drinking water
top-up relative to the free inlet
(opening, tank 3)
Operating Manual AC 3000-13500
Corrective action
Identify the leaky tapping points,
seal or repair them
Inform plumber/pressure
booster service
Actuate several times in manual
mode
Dismantle and clean the valve
Inform plumber
(cleaning/replacement)
Corrective action
Retighten hose connections
Reseal screw joints
Inform plumber (rectification)
Inform plumber (replacement)
Readjust position (the water jet
has to flow straight into tank 3
(clearance to free outlet 20 mm)
Reduce top-up
33