H: Noise
Fault
Aeration too loud
Drinking water top-up too loud
Stage 2 to stage 3 transfer
Gurgling
I: Red LED on display/system indicates error message/fault signalling lamp is active
Red LED/system emits beep
Fault signalling lamp
Red LED
Fault signalling lamp
Red LED
Fault signalling lamp
Red LED
Fault signalling lamp
Red LED
Fault signalling lamp
Red LED
Fault signalling lamp
34
Check (possible causes)
Low water level in tank 1 or 2
Air pump touches frame/tank
(structure-borne noise)
Transit support of the pump has
not been released
Manually activate top-up
Low water level in tank 3
Gurgling as water flows out of
the shower tray/bath tub
Messages
Interface 2
Electrodes 3
UV lamp defective 4
UV fault
Battery empty 5
Fault P1 / P2
Electrodes 3
Operating Manual AC 3000-13500
Corrective action
Temporary problem
Install air pump in a free-
standing position
Release transit support
(cable ties)
Due to on-site conditions
Due to on-site conditions
(temporary problem)
Check ventilation of grey water
feed.
Corrective action
Unplug the power plug of the
system and plug it in again
(reset)
Check both connecting cables
between control board and
display module
Inform plumber (replacement)
Sensors output values that are
not logical (e.g.min=0 / max=1)
Check sensor connections
Check UV components
(manual mode)
Inform plumber (replacement)
Replace battery on display
module (mode of operation is
not impaired)
The max. pump transfer time
was exceeded
Check the pump
Sensors output values that are
not logical (e.g.min=0 / max=1)
Check sensor connections