System components

Prefiltration

The vortex fine filter filters coarse constituents of the
grey water. The filter is regularly flushed by an
automatic backwashing unit according to time (I-filter
backwash) to counteract any blockage.
Filter backwash check:
The function can be checked by starting the backwash
manually. To do so, activate the filter backwash in the
Manual mode
Manual
The filter screen is then sprayed with clear water and
therefore cleaned.
Setting the automatic filter backwash interval:
In case of frequent, heavy soiling of the filter screen, it
makes sense for the automatic self-cleaning to be
carried out at shorter
adjusted accordingly in the Manual
I_Filter backwash menu.
Note!
Program times and timer values
should be adjusted in consultation
with the manufacturer.
300108/AV/Draft
Valve_Filter (VA3) menu.
intervals. The interval can be
Program times