10.5. ELS cooling system
NOTE
The introduction of cooling air using a fan or similar at firing chamber temperatures of 600°C
and above can damage the insulating material and the heating elements.
⇒
⇒
If the insulation material is damaged in the event of non-observance of the above-mentioned
information, the manufacturer assumes no liability for this.
The automatic cooling system of the ELS Frontloader is a fan for introducing cooling air, which is connected upstream
from the automatic supply air flap.
Figure 27: ELS cooling system
The automatic cooling system is operated and controlled via the control unit.
To do this, the appropriate event function in the particular kiln control system must be selected.
⇒
You must read the relevant instruction manual for the control system carefully!
Cold air may only be brought in at a temperature below 600°C.
When operating a cooling fan, the exhaust air opening must be open.
Automatic supply air flap
ELS cooling system