Table 279 : SOPAS error codes
Error code
Sopas_Ok
Sopas_Error_METHODIN_ACCESSDENIED
Sopas_Error_METHODIN_UNKNOWNINDEX
Sopas_Error_VARIABLE_UNKNOWNINDEX
Sopas_Error_LOCALCONDITIONFAILED
Sopas_Error_INVALID_DATA
Sopas_Error_UNKNOWN_ERROR
Sopas_Error_BUFFER_OVERFLOW
Sopas_Error_BUFFER_UNDERFLOW
Sopas_Error_ERROR_UNKNOWN_TYPE
Sopas_Error_VARIABLE_WRITE_ACCESSDENIED
Sopas_Error_UNKNOWN_CMD_FOR_NAMESERVER When using names instead of indices, a command
Sopas_Error_UNKNOWN_COLA_COMMAND
Sopas_Error_METHODIN_SERVER_BUSY
Sopas_Error_FLEX_OUT_OF_BOUNDS
Sopas_Error_EVENTREG_UNKNOWNINDEX
Sopas_Error_COLA_A_VALUE_OVERFLOW
Sopas_Error_COLA_A_INVALID_CHARACTER
Sopas_Error_OSAI_NO_MESSAGE
Sopas_Error_OSAI_NO_ANSWER_MESSAGE
Sopas_Error_INTERNAL
Sopas_Error_HubAddressCorrupted
8027168/1MNR/2024-10-25 | SICK
Subject to change without notice
Telegram structure: sFA ErrorCode
Description
No error
Wrong userlevel, access to method not allowed
Trying to access a method with an unknown Sopas
index
Trying to access a variable with an unknown Sopas
index
Local condition violated, e.g. giving a value that
exceeds the minimum or maximum allowed value
for this variable
Invalid data given for variable, this errorcode is dep‐
recated (is not used anymore).
An error with unknown reason occurred, this error‐
code is deprecated.
The communication buffer was too small for the
amount of data that should be serialised.
More data was expected, the allocated buffer could
not be filled.
The variable that shall be serialised has an
unknown type. This can only happen when there
are variables in the firmware of the device that do
not exist in the released description of the device.
This should never happen.
It is not allowed to write values to this variable.
Probably the variable is defined as read-only.
was issued that the nameserver does not under‐
stand.
The CoLa protocol specification does not define the
given command, command is unknown.
It is not possible to issue more than one command
at a time to an SRT device.
An array was accessed over its maximum length.
The event you wanted to register for does not exist,
the index is unknown.
The value does not fit into the value field, it is too
large.
Character is unknown, probably not alphanumeric.
Only when using SRTOS in the firmware and distrib‐
uted variables this error can occur. It is an indica‐
tion that no operating system message could be
created. This happens when trying to GET a varia‐
ble.
This is the same as
Sopas_Error_OSAI_NO_MESSAGE with the dif‐
ference that it is thrown when trying to PUT a varia‐
ble.
Internal error in the firmware, problably a pointer to
a parameter was null.
The Sopas Hubaddress is either too short or too
long.
ANNEXE
Dec.
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
N O T I C E D ' I N S T R U C T I O N | LMS4000
12
Hex.
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
10
11
12
13
14
15
147