Télécharger Imprimer la page

SICK LMS4000 Notice D'instruction page 112

Masquer les pouces Voir aussi pour LMS4000:

Publicité

12
ANNEXE
12.3.1.4.5.7
Define area in relative distance from the device. Only measurement points within this area are valid; all other
measurement points are transmitted in the telegram as invald (=0).
Table 146 : Telegram structure: sWN LFPcubicareafilter
Telegram structure: sWN LFPcubicareafilter
Telegram
Description
part
Command
Write
type
Command Set Rectangular Filter
Status
Activate/ deactivate
code
112
N O T I C E D ' I N S T R U C T I O N | LMS4000
Set Rectangular Filter [sWN LFPcubicareafilter]
(Authorized client)
Variable
Length
String
3
String
18
Bool_1
1
Additional details
Activate:
Deactivate:
Values CoLa A
Values CoLa B
(ASCII)
(Binary)
sWN
73 57 4E
LFPcubicareafil‐
4C 46 50 63
ter
75 62 69 63
61 72 65 61
66 69 6C 74
65 72
0
00
1
01
8027168/1MNR/2024-10-25 | SICK
Subject to change without notice

Publicité

loading