AVENTICS | RCM | R499050098–BDL–001–AD
6.1
Adjusting the end position system (SE/SH)
End cushioning element screwed in too far
Malfunctions and damage to the rotary compact module may
occur if the end cushioning element has been screwed in too
far.
Observe the notes on the reach of the screw (L) for the
O
end cushioning elements.
Maintain the permissible tightening torques for the lock nuts
O
(see Table 5 on page 54 and Table 6 on page 55).
Change the sealing rings after every tenth tightening.
O
NOTICE
53
Commissioning