Table 10:
RCM rotary compact module maintenance
Maintenance work
Changing the sealing rings
Checking the hydraulic shock absorbers
Lubrication
AVENTICS | RCM | R499050098–BDL–001–AD
7

Maintenance

System is operating under pressure!
Working on the system when it is under pressure could lead
to damage to the RCM rotary compact module, as well as
injuries!
Exhaust the entire system and all connected devices
O
before starting work.
The following work must be carried out on the RCM rotary
compact module – independent of the degree of utilization:
Versions
RCM-...-SH
Repairs to the RCM rotary compact module that go beyond
those listed in Table 10 are not permissible.
Contact your AVENTICS service department if you have any
technical problems.
CAUTION
RCM
After every 10th tightening
Recommendation: After 3 mil.
RCM
The bearings are maintenance-free