Commissioning
6.5
Trial run
1. Check if the following points have to be modified.
– Speed and acceleration of the moving masses
– End position (only with the rotary flange at a standstill)
– Mass of the useful load (only with the rotary flange at a
standstill)
– Position of the sensor (only with the rotary flange is at a
standstill)
2. Slowly open the check-choke valves until the desired
rotating speed has been set.
In doing so, the maximum permissible speed may not be
exceeded (see "Swivel time" in the chapter "Technical data"
on page 66).
The rotary flange should safely reach the end position
without any hard impacts. A hard impact will cause the
rotary flange to rebound out of the end position.
3. Interrupt the trial run if there is an audible impact of the
rotary flange.
Possible causes for hard impacts:
– Moving mass is too heavy
– Rotating speed is too high
– No compressed air cushion on the exhaust side.
4. Make sure you remedy the above-mentioned causes.
5. Repeat the trial run after you have completed all of the
necessary corrections.
6. Complete the trial run and firmly mount the sensor.