Malfunction
Asymmetric rotary movement of
the moving mass
Hard impacts in the end position
Rotary compact module does not
move
Rotary compact module only
moves very slowly
Rotary compact module does not
work throughout the entire
rotation range
Rotary compact module stops at
the intermediate position
AVENTICS | RCM | R499050098–BDL–001–AD

10 Troubleshooting

Possible cause
Throttles used incorrectly
Speed is too high
No cushioning or too little
cushioning
Air cushion missing
Defective shock absorber
Useful load is too heavy
Compressed air supply is missing Check the compressed air supply
Hosing fault
Useful load is too heavy
Control pulse is missing
Sensor is defective
Compressed air supply is too low Check the compressed air supply
Defective sealing rings
Throttles set incorrectly
Defective piston seal
End position system set
incorrectly
Hosing fault
Defective rotary compact module The rotary compact module must
Troubleshooting
Remedy
Check the throttle function (air
supply or exhaust)
Reduce the speed
Readjust the cushioning
elements
Simultaneously ventilate both
compressed air connections and
then exhaust one side
Exchange the shock absorber
Reduce the useful load
Check the hoses and blanking
plugs
Reduce the useful load
Check the control valve
Exchange the sensor
Change the sealing rings
Check the throttle setting
The rotary compact module must
be checked by AVENTICS
Check the end position system
Check the hoses
be checked by AVENTICS
65