88
AVENTICS | CL03, CL03-XL | R402000141–BAL–001–AF
Conversion and Extension
8.2.3 Removing the end plate
Fig. 11: Removing the end plate
1. Remove the end plate (4) by undoing the three hexagon
screws (20) using an 8 mm wrench.
8.2.4 Installing subbases
In order to install subbases, the corresponding number
of tie rod extensions, consisting of three tie rods and three
tie rod nuts, are required depending on the number
of valves. Tie rod extensions for valve systems CL03
and CL03-XL can be found in the online catalog
(www.aventics.com/pneumatics-catalog).
4
20