A rodent guard (minimum 1/4" wire mesh) must be used at the termination (E). All connections must
be secured and airtight by either using the appropriately sized hose clamp and/or UL-181-AP foil tape.
Make sure that the fresh air intake backdraft shutter (F) functions freely. The fresh air intake
backdraft shutter is located in the back of the stove.
Sources of Outside Combustion Air
IT IS FORBIDDEN TO DRAW COMBUSTION AIR FROM A BASEMENT, AN ATTIC, A GARAGE OR ANY
CONFINED SPACE.
You can draw air from a ventilated crawl space underneath the floor.
You can draw air directly from an outside wall, behind the stove.
90
Stove Builder International Inc. | 48202 | Rev: May 31 2019 10:15AM | Uncontrolled Copy
(90 OF 91)
WARNING
Cambridge II and Osburn 3000C Pellet Stove Installation and Operation Manual