Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on
6/17/2019 7:40:40 AM
TEST REPORT 103819589MTL-001
TEST REPORT FOR STOVE BUILDER INTERNATIONAL INC.
Report No.: 103819589MTL-001
Date: 03/26/19
100
TOTAL PARTICULATE WEIGHT – ASTM E2515
PARTICULATE CONCENTRATION – ASTM E2515
where:
K
2
TOTAL PARTICULATE EMISSIONS (g) – ASTM E2515
PROPORTIONAL RATE VARIATION (%) – ASTM E2515
MEASUREMENT OF UNCERTAINTY – ASTM E2515
GENERAL FORMULA – ASTM E2515
Where:
δY/δx
i
u
i
TOTAL PARTICULATE EMISSIONS – ASTM E2515
where:
c
s
c
r
Q
std
θ
MU OF c
Version: 05/10/17
Stove Builder International Inc. | 48202 | Rev: May 31 2019 10:15AM | Uncontrolled Copy
= Conversion to percent.
M
= m
+ m
+ m
n
p
f
g
C
= K
(m
/V
)
g/dscm (g/dscf)
s
2
n
m(std)
= 0.001 g/mg
E
= (C
– C
)Q
θ
T
s
r
std
PR = [θ(V
V
T
T
)/(10(V
mi
s
m
si
m
2
MU
= √0.1
• X
weighing
2
uY = √((δY/δx
) x u
)
+ ... + ((δY/δx
1
1
= Partial derivative of the combining formula with respect to individual measurement xi,
= is the uncertainty associated with that measurement.
E
= (c
– c
) Q
θ
T
s
r
std
= sample filter catch/(sample flow rate x test duration), g/dscf,
= room background filter catch/(sample flow x sampling time), g/dscf,
= average dilution tunnel flow rate, dscf/min, and
= sampling time, minutes.
s
c
= F
/(Q
x θ) = 0.025/(0.25 x 180) = 0.0005555
s
c
sample
δc
/δF
= 1/Q
• Θ = 1/0.25 • 180 = 0.0222
s
c
sample
2
δc
/δQ
= -F
/Q
• Θ = -0.025/0.25
s
sample
c
sample
2
δc
/δΘ = -F
/Q
• Θ
= -0.025/0.25 • 180
s
c
sample
MUc
= √(0.00027 • 0.0222)
s
(12 OF 20)
V
T
T
)] x 100
si
s
mi
2
) x u
)
n
n
2
• 180 = -0.00222
2
= -0.000003
2
2
+ (0.0025 • - 0.00222)
Page 12 of 20
1829, 32nd AVenue
Lachine, Quebec, Canada, H8T 3J1
Telephone: (514)631-3100
Facsimile: (514)631-1133
www.intertek.com/building
GFT-OP-10c
Page 808 of 864