Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on
6/17/2019 7:40:40 AM
1 - MANUAL ENGLISH
APPENDIX D: MOBILE HOME INSTALLATION
Anchoring the stove
FOR MOBILE HOME INSTALLATION, IT IS MANDATORY TO CONNECT THE STOVE TO AN OUTSIDE
COMBUSTION AIR SOURCE (SEE APPENDIX E – COMBUSTION AIR SUPPLY).
When installed in a mobile home, the stove must be anchored to the floor with two screws. Use the
two anchoring holes (A) located for this purpose on each side of the pedestal, as shown on the
following image.
For use in a mobile home in Canada, this pellet stove must be connected to a vent system certified
according to the standard or ULC/ORD-C441 CAN/ULC-S609. A vent system meeting the requirements
of ULC S629M can also be used.
For use in a manufactured home in the United States, this pellet stove must be connected to a venting
system that meets the requirements of UL 641 standard. A vent system that meets the requirements
of UL 103 standard may also be used.
Cambridge II and Osburn 3000C Pellet Stove Installation and Operation Manual
Stove Builder International Inc. | 48202 | Rev: May 31 2019 10:15AM | Uncontrolled Copy
(87 OF 91)
WARNING
87
Page 94 of 864