Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on
6/17/2019 7:40:40 AM
1 - MANUAL ENGLISH
1 CAMBRIDGE II AND OSBURN 3000C II and OSBURN 3000C GENERAL
INFORMATIONS
1.1 Appliance performance
Fuel type
Recommended heating area
Hopper capacity
Maximum burn time
Maximum heat input rate
Overall heat output rate (min. to max.)
Average overall efficiency
Optimum efficiency
Burn rate
Average particulate emissions rate
(8)
Average CO
Average electrical power consumption
[*]
Recommended heating area and maximum burn time may vary subject to location in home, chimney draft, heat
loss factors, climate, fuel type,
appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature
considering that the space configuration and the presence of heat distribution systems have a significant impact in
making heat circulation optimum.
( )
Grades of pellet fuel are determined by organizations such as Pellet Fuels Institute (PFI), ENplus and CANplus.
(1)
Values are as measured per test method, except for the recommended heating area, hopper capacity, maximum
burn time and maximum heat input rate. Results may vary depending on pellet quality, density, length, and
diameter.
(2)
Based on the maximum burn-rate and a dry energy value of pellet at 8,600 BTU/lb.
(3)
As measured per CSA B415.1-10 stack loss method.
(4)
Higher Heating Value of the fuel.
(5)
Lower Heating Value of the fuel.
(6)
Optimum overall efficiency at a specific burn rate (LHV).
(7)
This appliance is officially tested and certified by an independent agency.
(8)
Carbon monoxide.
(9)
Unless stated otherwise, measures were taken directly at the main power source and include all electrical
components present in the appliance.
6
Stove Builder International Inc. | 48202 | Rev: May 31 2019 10:15AM | Uncontrolled Copy
(6 OF 91)
(1)
Wood Pellet (Premium grade or better)
[*]
500 to 2,200 ft
60 lb (27 kg)
[*]
50 h
(2)
43,000 BTU/h (12.6 kW)
(3)
7,200 BTU/h to 23,000 BTU/h (2.1 kW to 6.74 kW)
(3)
(6)
90%
1.0 lb/h to 3.8 lb/h (0.46 kg/h to 1.74 kg/h)
(7)
0.96 g/h (EPA / CSA B415.1-10)
9.54 g/h
3.5A (420W) for ignition cycle
(9)
2.3A (276W) min. / 3.1A (372W) max. for continuous
operation
feed rate, fuel level,
and other variables. The recommended heated area for a given
Cambridge II and Osburn 3000C Pellet Stove Installation and Operation Manual
2
2
(46 to 185 m
)
(4)
76% (HHV
)
( )
(5)
82% (LHV
)
Page 13 of 864