TEST REPORT 103819589MTL-001
TEST REPORT FOR STOVE BUILDER INTERNATIONAL INC.
Report No.: 103819589MTL-001
Date: 03/26/19
SECTION 10
TEST RESULTS
DESCRIPTION OF TEST RUNS:
RUN #1/Integrated (February 25
conditioning. Sampling started for 1h at high fire. Stove was set to medium fire (5/12) for 2h.
Stove was finally set to low fire (1/12) for 3h.
TABLE 1 – EMISSIONS
RUN#
Int.
*Notes: H= High burn rate, M= Medium burn rate, L= low burn rate, OA= overall burn rate.
TABLE 2 – TEST FACILITY CONDITIONS
RUN
#
Int.
TABLE 3 – DILUTION TUNNEL FLOW RATE MEASUREMENTS AND SAMPLING DATA
RUN
#
Int.
TABLE 4 - DILUTION TUNNEL DUAL TRAIN PRECISION
RUN
#
Int.
Version: 05/10/17
Stove Builder International Inc. | 48202 | Rev: May 31 2019 10:15AM | Uncontrolled Copy
th
2019): Stove burned for 1h at highest setting (12/12) for
TEST
BURN RATES
PARTICULATE
DATE
(kg/hr)(Dry)
EMISSION
RATE (g/hr)
H*
0.46
M*
0.86
Feb. 25th,
2019
L*
1.74
OA*
0.8
ROOM
ROOM
BARO
TEMP
TEMP
PRES
BEFORE
AFTER
BEFORE
(°F)
(°F)
(in/Hg)
71
76
29.1
BURN
VELOCITY
VOLUMETRIC
TIME
(ft/sec)
FLOW RATE
(min)
(dscf/min)
360
16.80
329.63
SAMPLE RATIOS
TOTAL EMISSIONS (g)
TRAIN 1
TRAIN 2
TRAIN 1
2636
2593
6.063
(17 OF 20)
st
1
HOUR
CO EMISSIONS
EMISSIONS
(g)
0.96
2.53
BARO
R. H.
R. H.
PRES
BEFORE
AFTER
AFTER
(%)
(%)
(in/Hg)
29.4
25
26
AVG TEMP
SAMPLE VOLUME
(°R)
(dscf)
1
540
45.017
DEVIATION (%)
TRAIN 2
5.446
5.36%
Page 17 of 20
1829, 32nd AVenue
Lachine, Quebec, Canada, H8T 3J1
Telephone: (514)631-3100
Facsimile: (514)631-1133
www.intertek.com/building
HEATING
(g/min)
EFFICIENCY
(%HHV)
0.16
76%
AIR VEL
AIR VEL
BEFORE
AFTER
(ft/min)
(ft/min)
0
0
PARTICULATE
CATCH (mg)
2
1
2
45.759
2.3
2.1
DEVIATION (g/kg)
0.12
GFT-OP-10c