TEST REPORT 103819589MTL-001
TEST REPORT FOR STOVE BUILDER INTERNATIONAL INC.
Report No.: 103819589MTL-001
Date: 03/26/19
TEST METHOD PROCEDURES
LEAK CHECK PROCEDURES
Before and after each test, each sample train is tested for leaks. Leakage rates are measured
and must not exceed 0.02 CFM or 4% of the sampling rate. Leak checks are performed checking
the entire sampling train, not just the dry gas meters. Pre-test and post-test leak checks are
conducted with a vacuum of 10 inches of mercury. Vacuum is monitored during each test and
the highest vacuum reached is then used for the post-test vacuum value. If leakage limits are
not met, the test run is rejected. During, these tests the vacuum was typically less than 2 inches
of mercury. Thus, leakage rates reported are expected to be much higher than actual leakage
during the tests.
TUNNEL VELOCITY/FLOW MEASUREMENT
The tunnel velocity is calculated from a center point Pitot tube signal multiplied by an
adjustment factor. This factor is determined by a traverse of the tunnel as prescribed in EPA
Method 1. Final tunnel velocities and flow rates are calculated from EPA Method 2, Equation
6.9 and 6.10. (Tunnel cross sectional area is the average from both lines of traverse.)
Pitot tubes are cleaned before each test and leak checks are conducted after each test.
PM SAMPLING PROPORTIONALITY
Proportionality was calculated in accordance with ASTM E2515-11. The data and results are
included in Appendix B.
DEVIATIONS FROM STANDARD METHOD:
No deviation from standard method.
SECTION 8
TEST CALCULATIONS
NOMENCLATURE FOR ASTM E2515:
A
B
ws
C
p
c
r
c
s
E
T
Version: 05/10/17
Stove Builder International Inc. | 48202 | Rev: May 31 2019 10:15AM | Uncontrolled Copy
= Cross-sectional area of tunnel m2 (ft2).
= Water vapor in the gas stream, proportion by volume (assumed to be 0.02 (2.0 %)).
= Pitot tube coefficient, dimensionless (assigned a value of 0.99).
= Concentration of particulate matter room air, dry basis, corrected to standard
conditions, g/dscm (gr/ dscf) (mg/dscf).
= Concentration of particulate matter in tunnel gas, dry basis, corrected to standard
conditions, g/dscm (gr/dscf) (mg/dscf).
= Total particulate emissions, g.