5.1.6 Combustion Settings and Pilot Settings depending on Fuel Quality

5.1.6.1 Pilot adjustment (pilot settings adjustment)
The "PILOT ADJUSTEMENT" will allow you to modify default settings by ±5% for auger motor 1 and
±10% for combustion and exhaust fan, but will only apply during pilot cycle. To restore default setting,
select "DEFAULT".
5.1.6.2 Combustion adjustment (fuel quality adjustment)
The "COMBUSTION ADJUSTMENT" will allow you to modify default settings by ±5% for auger motor 1
and ±10% for combustion and exhaust fan. To restore default setting, select "DEFAULT".
Here are some situations where you may want to adjust these components:
Average speed of auger motor #1:
You may want to increase the auger motor #1 speed if fire goes out when combustion level is at its
minimum setting. When burning poor quality pellets you may also need to reduce the auger motor
speed to avoid unburned pellets to fall into the ash drawer at any combustion level.
Cambridge II and Osburn 3000C Pellet Stove Installation and Operation Manual
Stove Builder International Inc. | 48202 | Rev: May 31 2019 10:15AM | Uncontrolled Copy
(31 OF 91)