6 STOVE OPERATION

6.1 First Startup

Before starting your stove, make sure that the burn pot, the baffles and the maintenance access
panels are properly installed. Make sure that the stove and the hopper have been emptied of all tools
and accessories (see Section 2.3: Before Operating Your Stove). Also make sure that the venting
system is properly sealed, that all doors and hopper lid are closed. Make sure that the hopper is full of
pellets. Press the "ON/OFF"
green to yellow during the igniting mode.
If fire doesn't start within 20 minutes, a warning code
troubleshooting section for more details.
WARNING: NEVER USE A GRATE OR OTHER MEANS OF SUPPORTING THE FUEL. ONLY USE THE
APPROVED STOVE BURN POT.

6.2 Everyday Startup

Before starting the stove, make sure there is enough pellets in the hopper and that the recommended
maintenance schedule has been followed (see Section 8.1.1 Recommended maintenance schedule)
then press the "ON/OFF"
green to yellow during the igniting mode.

6.3 Running Out of Pellets

If your stove runs out of pellets, the fire will slowly go out; the convection fan will run until the heat
sensor on the exhaust fan reads 115°F. The cooling cycle will take a few minutes before all other
motors stops. When this temperature is reached, a warning message "NO FUEL" will be displayed on
the LCD screen.
To restart the stove, wait until all components stop running (usually 10 minutes after the warning
message has been displayed). Press the "RESET" button, refill the hopper, and press the "ON/OFF"
icon on the main status page.
Cambridge II and Osburn 3000C Pellet Stove Installation and Operation Manual
Stove Builder International Inc. | 48202 | Rev: May 31 2019 10:15AM | Uncontrolled Copy
(37 OF 91)
icon on the main status page. Note that the button will flash from

FAILED IGNITION

THE EXHAUST
TEMPERATURE HAS NOT
REACHED ITS START-UP
IGNITION ATTEMPS
icon on the main status page. Note that the button will flash from
will appear. Refer to
UE AFTER TWO
37
Page 44 of 864