Installation Configurations; Installation Warnings, Cautions And Recommendations Reminder - SBI CAMBRIDGE II Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on
6/17/2019 7:40:40 AM
1 - MANUAL ENGLISH
United States:
Not Less than 36" (91 cm) above any forced air inlet located within 120" (305 cm);
Not Less than 48" (122 cm) below and horizontally from, or 12" (30 cm) above, any door, window
or gravity air inlet into any building;
Not Less than 24" (61 cm) from an adjacent building and not less than 84" (213 cm) above grade
when located adjacent to a public walkway;
Cannot be located less than 12" (30 cm) above grade;
Cannot be located above a gas meter/regulator within 36" (91cm) horizontally of the vertical
center line of the regulator;
Not within 6 feet (183 cm) of a gas service regulator vent outlet;
Other restrictions may apply. See NFPA 211 for further information.
3.4.1.1
Direct Vent System (2-in-1 Exhaust and fresh air intake)
In Canada: The permitted termination location for a direct vent system are the same than those
permitted with a regular pellet vent system.
In the Unites States : The permitted termination location for a direct vent system are the same than
those permitted with a regular pellet vent system except for the following : The exit terminal shall be
located not less than 9" (23 cm) from any opening through which vent gases could enter a building.

3.5 Installation Configurations

3.5.1 Installation Warnings, Cautions and Recommendations Reminder

PROFESSIONNAL INSTALLATION IS HIGHLY RECOMMENDED.
THIS STOVE USES A PRESSURIZED VENTING SYSTEM. ALL VENT CONNECTOR JOINTS MUST BE
SEALED AND FASTENED. YOU MAY USE RTV SILICONE (ROOM TEMPERATURE VULCANISATION),
METALLIC TAPE, AND A MINIMUM OF THREE SELF-TAPING SCREWS AT ALL JOINT
CONNECTIONS TO ENSURE A TIGHT SEAL. CONSULT THE PELLET VENT MANUFACTURER'S
INSTRUCTION TO ENSURE PROPER INSTALLATION, CONSISTENT PERFORMANCE, AND TO
AVOID SMOKE AND ASH SPILLAGE.
THE CHIMNEY CONNECTOR SHALL NOT PASS THROUGH AN ATTIC OR ROOF SPACE, CLOSET OR
SIMILAR CONCEALED SPACE OR FLOORS OR CEILING.
INSTALL VENTING SYSTEM AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.
THE USE OF A SPARK ARRESTER AT THE END OF THE TERMINATION IS MANDATORY. IT IS
IMPORTANT THAT THE SPARK ARRESTER BE CLEAR OF ANY DEBRIS AT ALL TIME.
Cambridge II and Osburn 3000C Pellet Stove Installation and Operation Manual
Stove Builder International Inc. | 48202 | Rev: May 31 2019 10:15AM | Uncontrolled Copy
(17 OF 91)
CAUTION
17
Page 24 of 864

Publicité

Chapitres

Table des Matières
loading

Produits Connexes pour SBI CAMBRIDGE II

Table des Matières