Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on
6/17/2019 7:40:40 AM
1 - MANUAL ENGLISH
12.2 Combustion blower
1. Remove the decorative panel on the right hand side. Then, Remove the two screws (A) that hold
the panel at the back of the stove. Open and lift the panel to take it off the stove.
Unlatch the clamps (C). Remove the backdraft shutter (G) and the gasket (D). Pull the combustion
blower (F) and unplug the wire connector from the harness. Remove the plug (E) of the blower.
Cambridge II and Osburn 3000C Pellet Stove Installation and Operation Manual
Stove Builder International Inc. | 48202 | Rev: May 31 2019 10:15AM | Uncontrolled Copy
(67 OF 91)
67
Page 74 of 864