Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on
6/17/2019 7:40:40 AM
1 - MANUAL ENGLISH
HORIZONTAL RUNS SHALL NOT EXCEED 9 FEET.
NEVER EXCEED 30 FEET OF EVL.
Here is an example to help you calculate Equivalent Vent Length. On the following figure the EVL can
be calculated like this:
2 horizontal run of 1' = (2 X 1') X 1' = 2' of EVL
1 elbow 90° or "Tee" = 5' of EVL
3 vertical length of 4' = (3 X 4') X 0.5' = 6' of EVL
Total EVL = (2' + 5' + 6') = 13'
Since the total EVL is less than 15 feet, the recommended exhaust venting diameter is 3".
Cambridge II and Osburn 3000C Pellet Stove Installation and Operation Manual
Stove Builder International Inc. | 48202 | Rev: May 31 2019 10:15AM | Uncontrolled Copy
(13 OF 91)
Qty
Type of pipe
1
90° elbow or "T"
1
45° elbow
1 foot
Horizontal pipe run
1 foot
Vertical pipe run
CAUTION
Equivalent Length (EVL)
5 feet
3 feet
1 foot
0.5 foot
13
Page 20 of 864