Installation inside your shop
We suggest you to install the blast chiller/freezer
inside an air-conditioned room. We kindly remind
you that without this facility, malfunction may occur
(for example condensation etc).
ATTENTION!
In order to allow a good functioning of the blast
chiller/freezer please draw attentions to the follow-
ing instructions.
• Do not place the blast chiller to a direct exposure
of sunlight and to all the other means of irradia-
tion, such as high intensity incandescent lights,
cooking ovens, heating radiators.
• Do not place the blast chiller close to external
exits into draught, such as doors, windows, air
vent or air conditioning fans.
• Do not obstruct the blast chiller air inlet.
Minimum wall distance
EN
In order to allow a good blast chiller functioning and
a correct air circulation, during the positioning you
have to respect some minimum wall distance as
follows:
Blast chiller with built in condensing unit
The blast chiller is provided with built in condensing
unit, therefore it is necessary not to obstruct the
blast chiller air inlet corresponding to the front grid
for the air extraction in order to allow a proper air
circulation. Keep clear the whole blast chiller pe-
rimeter. We remind you that room temperature ris-
es or insufficient quantity of air to the unit condens-
er, reduce the blast chiller performances with
6
• Do not place any kind of material on the blast
chiller. Keep clear the whole blast chiller perim-
eter in order to allow a proper air circulation.
• Do no place the blast chiller into an high relative
humidity room (condensate water creation is
possible)
• Do not place the blast chiller inside a closed cav-
ity. Without a proper air circulation the refrigera-
tion unit will not work effi ciently.
• Do not place hot trays or pans on the top of the
blast chiller.
Verify that in the installation room there is enough
air turnover, even during closing and rest hours.
In this way the expansion/condensing unit will
work correctly.
• Keep a minimum distance, corresponding to the
door opening length, from the front unit grid
view.
• Keep a minimum 10 cm distance of the blast
chiller back from the wall.
possible deterioration of the products and more
energy consumption. If the blast chiller with built in
condensing unit was leant on the side during trans-
portation we suggest you to keep the product in up-
right position for at least 8 hours, before switching
it on. In this way, you will allow the oil to flow in all
the components, lubricating them again. After-
wards you can proceed with the starting.