ATTENTION!
At the end of the positive process phase, the con-
servation program is set automatically at the tem-
perature of 0 to +3°C.
At the end of the negative process phase, the con-
Alarms
The existing alarms are those related to the probes.
They are shown only when it is required the view of
the relative probe. "Er" Generic or internal error of
the probes.
"Er" generic error or inside the probe
"ErI" room probe error
"Er2" core probe error
Regulations
Compressor
The compressor can be active only in START func-
tion when the room probe has no error.
If the presence of door is on (PI=I), the door must be
closed to permit the starting of the compressor only
EN
if P6=0. With P6=0 the compressor is active even if
the door is open and with arrested fan. The com-
pressor starts according to the SET POINT on, cor-
responding to the selected cycle and according to
the differential of temperature set (Parameter P8).
Manual defrosting
The defrosting is carried out with open door, without the use of neither the heater nor the hot gas.
Parameters
Pressing contemporarily
ter the parameter setting for at least 4 sec.
At this point on the display appears the number it-
self of the parameter (P0). Pressing the SET
it is possible to see the value of the parameter itself
and modify it.
16
Up and Down
to en-
key,
SET
servation program is set automatically at the tem-
perature of -22 to -25°C.
In order to respect the chilling and freezing time
provided by law, while a cycle is in progress, it is
strongly advised against opening the door of the de-
vice.
If one program is in progress and an error is gener-
ated, the cycle passes to time process even if the
error continues to be on.
The protection time for the compressor are:
• P9: minimum delay that must exist between the
switching off and the next starting up of the com-
pressor. This parameter is used also like reset of
the card.
• P10: minimum delay that must exist between 2
consecutive starting ups of the compressor.
The keys
Up and Down
setting is on, allow to pass to the next/former pa-
rameter; when the value of the parameter is on,
they modify it.
, when the parameter