Substitution of the fan motor
If the device is provided with a fan motor and it is
necessary to remove it, it is important to taking off
the tension, verify the label with technical data of
Substitution of the compressor / refrigerated gas
In case of compressor damaging and/or replacing,
save its refrigerating gas and oil and avoid disper-
Requesting spare parts
When requesting spare parts, please say clearly:
• Model of the item
• Serial number of the item
10. Maintenance – disposal of materials
Message
Breakdown malfunction
Ensure that all the cables are included in
ER
the terminal
Ensure that all the cables are included in
ER1
the terminal
EN
Ensure that all the cables are included in
ER2
the terminal
Blasting time too long
Failed conservation of the food at he end
of the blasting cycle
Ensure that all the cables are included in
ER2
the terminal
The door is open
DR
18
the fan motor and substitute it with one of identical
power, voltage and frequency.
sing it in the environment.
• Quantity of the spare part
Possibly, enclose also a picture of the part to be or-
dered.
Error
Generic error or/ internal
error of the probe
Error of the room probe
Error of the room probe
Check if the evaporator is
blocked with ice
Check if the product is
loaded correctly and does
not exceed
Check if the internatl fan is
spinning
Ensure that the laboratory
temperature is not too high
and with high percentage
of humidity
Error of the room probe
The door is open
Solutions
If the cable is tore off.
insere it again and screw it
up
If the cable is tore off.
insere it again and screw it
up
If the cable is tore off.
insere it again and screw it
up
Leave the door open for at
least 15 min to melt the ice
Lighten the load of trays
and grills
Contact rhe assisatnce
Contact rhe assisatnce
Contact rhe assisatnce
If the cable is tore off.
insere it again and screw it
up
Check that the door is
properly closed