TRANSPORT AND STORAGE
• Transport shackle built onto pressure port as at-
tachment point
• Installation and operating instructions:
• Unit: separate instructions for hydraulics and
motor
• "Bare shaft" version: Instructions for hydraulics
• CE-declaration

3.9. Accessories

• Connection cable, sold by the metre
• External pencil electrode for sealing chamber
control
• Level control devices
• Fixation accessories and chains
• Switchgear, relays and plugs

4. Transport and storage

NOTE
Also note all the information regarding trans-
port and storage in the operating and mainte-
nance manual for the motor!
4.1. Delivery
On delivery, check immediately that the ship-
ment is complete and undamaged. If any parts
are damaged or missing, the transport company
or the manufacturer must be notified on the day
of delivery. Claims made after this date cannot be
recognised. Damage to parts must be noted on
the freight documentation.
4.2. Transport
Only the appropriate and approved fastening
devices, transportation and lifting equipment may
be used. These must have sufficient load-bearing
capacity to ensure that the hydraulics can be
transported safely. If chains are used they must
be secured against slipping.
The personnel must be qualified for the tasks and
must follow all applicable national safety regula-
tions during the work.
The hydraulics is delivered by the manufacturer or
shipping agency in suitable packaging. This nor-
mally precludes the possibility of damage occur-
ring during transport and storage. The packaging
should be stored in a safe place for reuse if the
product is frequently used at different locations.
Note the additional information in the operating
and maintenance manual for the motor regard-
ing transport.
4.3. Storage
Newly supplied hydraulics are prepared so that
they can be stored for at least 1 year. The hydrau-
lics should be cleaned thoroughly before they are
put into temporary storage.
Note the additional information in the operating
and maintenance manual for the motor regard-
ing storage.
Installation and operating instructions Wilo-RexaBloc RE
The following should be taken into consideration
for storage:
• Place the hydraulics on a firm surface and secure
it against slipping and falling over. Sewage hy-
draulics are stored horizontally.
DANGER due to falling over!
Never set the hydraulics down if unsecured.
If the hydraulics falls over, this may lead to
injuries!
• Our hydraulics can be stored at temperatures
down to -15 °C. The store room must be dry. We
recommend a frost-protected room for storage
with a temperature between 5 °C and 25 °C.
• The hydraulics must not be stored in rooms in
which welding work is carried out, because the
resulting gases or radiation can damage the elas-
tomer components and coating.
• Suction and pressure connections must be sealed
securely to prevent contamination getting in.
• The hydraulics must be protected from direct
sunlight, heat, dust, and frost. Heat or frost can
cause serious damage to impellers and coatings!
• The impellers should be checked at regular inter-
vals. This presents jamming of the bearings and it
renews the film of lubrication on the mechanical
seal.
BEWARE of sharp edges!
Sharp edges may form on the impeller and
on the openings of the suction and pressure
ports. There is a risk of injury! Wear the nec-
essary protective clothing, such as protective
gloves.
• If the hydraulics has been stored for a long period
of time, it should be cleaned of impurities such as
dust and oil residue before commissioning. Check
that the impellers move freely and check the
housing coatings for damage.
Prior to commissioning, the fill level in the seal-
ing chamber should be checked and topped up,
if necessary!
Damaged coatings must be repaired immedi-
ately. Only an intact coating fulfils its intended
purpose.
Please note that elastomer parts and coatings
become brittle over time. If the product is to be
stored for longer than 6 months, we recommend
checking these parts and replacing them as nec-
essary. Consult Wilo customer service for details.

4.4. Return delivery

Hydraulics that are returned to the factory must
be properly packaged. This means that impuri-
ties have been removed from the hydraulics and
that it has been decontaminated if used to pump
fluids that are hazardous to health.
For shipping, the parts must be packed in tear-
proof plastic bags of sufficient size in such a
manner that they are tightly sealed and leak-
proof. Furthermore, the packaging must protect
English