T.06 External heating pump
T.23 Oil sump heater
T.22 EEV 2 position
T.127 External back-up heater
E.8
Menu item: Diagnostics codes
MENU | SETTINGS | Installer level
Diagnostics codes
0 - 99
D.000 Heating energy yield: Day
D.001 Cooling energy yield: Day
D.002 DHW energy yield: Day
D.004 DHW cylinder temp.
D.005 Targ. compressor flow temp.
D.007 Target DHW cylinder temp.
D.014 Heating energy yield: Month
D.015 Heating working fig.: Month
D.016 Heating energy yield: Total
D.017 Heating working fig.: Total
D.018 DHW energy yield: Month
D.019 DHW working fig.: Month
D.022 DHW energy yield: Total
D.023 DHW working fig.: Total
D.027 MO 1 relay status
D.028 MO 2 relay status
D.033 Compressor energy integral
D.035 External 3-port valve
D.036 Electr. power consumption
D.037 Compressor modulation
D.038 Air inlet temperature
D.040 Compressor flow temp.
D.041 Compressor return temp.
D.043 Heat curve
D.044 Cooling energy yield: Total
D.045 Cooling working fig.: Total
D.048 Cooling working fig.: Month
D.049 Cooling energy yield: Month
D.050 Environment circuit output
D.060 Building circuit flow rate
D.061 Building circ. water pressure
D.064 Total operating hours
D.066 Cooling operating hours
D.067 Compressor anti-cycl. time
D.071 Flow temperature
D.072 Back-up heater op. hours
D.073 Imm. heater energy cons.
D.074 Back-up heater switch. ops
D.076 Output of the back-up heater
D.077 Total energy consumption
D.080 Heating operating hours
D.081 DHW operating hours
248
For the automatic selection ON, factory setting: OFF
On, Off
1–100%, increment 1, factory setting: 0
On, Off
Current value in kWh
Current value in kWh
Current value in kWh
Current value in °C
Current value in °C
Adjustable value 35–70 in °C, factory setting: 35
Current value in kWh
Current value, decimal
Current value in kWh
Current value, decimal
Current value in kWh
Current value, decimal
Current value in kWh
Current value, decimal
Current value
Current value
Current value in °min
Open, closed
Current value in kW
Current value in percent
Current value in °C
Current value in °C
Current value in °C
0.1 to 4.0, increment 0.05, factory setting: 0.6
Current value in kWh
Current value, decimal
Current value, decimal
Current value in kWh
Current value in kW
Current value in litres per hour
Current value in bar
Current value in hours
Current value in hours
Current value in minutes
15 to 90 °C, increment 1.0, factory setting: 55
Current value in hours
Current value in kWh
Current value, decimal
Current value in kW
Current value in kWh
Current value in hours
Current value in hours
Installation and maintenance instructions 8000017440_FT