Running the installation assistants
The installation assistant is launched when the product is
switched on for the first time. It provides direct access to
the most important check programmes and configuration
settings for starting up the product.
MENU | SETTINGS | Installer level | Installation assistant
Confirm the launch of the installation assistant. All heating
and domestic hot water demands are blocked whilst the in-
stallation assistant is active.
Set the following parameters:
–
Language, date, time
–
System control present
–
Check programme: Fill the building circuit with water
–
Check programme: Purge building circuit
–
Immersion heater power supply (electric back-up heater)
–
Immersion heater output limit (electric back-up heater)
–
Cooling technology
–
Contact details, company, phone number
To access the next item, confirm by pressing
case.
If you do not confirm the launch of the installation assistant,
it is closed 10 seconds after you switch on the unit and the
basic display then appears. If the installation assistant does
not run through completely, it restarts the next time the unit
is switched on.
8.7.1
Setting the language
1.
Open: MENU | SETTINGS | Language, time, display
2.
Scroll to select the required language and confirm by
pressing
.
8.7.2
Name and telephone number of the
competent person
You can store your name and your phone number in the
product menu.
The end user can display both of these in the Information
menu. The telephone number can be up to 16 digits long and
must not contain any spaces.
Scroll as far as possible to the left to delete the character.
Scroll as far as possible to the right to save the entry.
8.7.3
Ending the installation assistant
▶
Once you have run through the installation assistant suc-
cessfully, confirm by pressing
◁
The installation assistant will close and will not launch
again when the product is next switched on.
226
in each
.
8.8
Menu functions without the optional system
control
If the "System control" request in the installation assistant is
denied, the following additional functions are displayed in the
indoor unit's control panel:
–
End user level (without control module)
–
Permanent cooling
–
Desired temperature:
–
Green iQ:
–
Actual flow temperature:
–
Water pressure:
–
Energy data
–
Heat pump module
–
Heat pump
–
End user level (with control module)
–
Zone:
–
Heating
–
Cooling
–
Absence
–
Cooling for several days
–
DHW
–
Rapid DHW
–
Ventilation boost
–
Installation off
–
Installer level (without control module or system control)
–
Data overview
–
Installer contact info
–
Service date:
–
Test modes
–
Diagnostics codes
–
Fault history
–
Limp home mode history
–
Installation configuration
–
Screed drying
–
Reset
–
Factory settings
The system control can only be retroactively deactivated
to use the additional functions in the indoor unit's control
panel (AAI functions) if the product is reset to the factory
settings, and the installation assistant is then run again and
the function is confirmed without the system control.
8.9
Energy balance control
The energy balance is the integral from the difference
between the flow temperature actual value and target value,
which is added up every minute. If the set heat deficit (WE =
-60°min in heating mode) is reached, the heat pump starts.
If the supplied heat volume corresponds to the heat deficit
(integral = 0°min), the heat pump is switched off.
The energy balancing is used for heating and cooling mode.
Installation and maintenance instructions 8000017440_FT